Showing results: 106 - 120 of 278 items found.
-
Applied Meters, a.s.
The Reference Standard RS is precision standard meter in single- and three-phase version for electrical power and energy measurement. It is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any true or artificial mode of operation in three phase system and is capable to evaluate individual quantities in any phase
-
PH-ASE -
HenergySolar
The PH-ASE spectroscopic ellipsometer measures thickness, refractive index and extinction coefficient of single films and multilayer stacks. Reflection measurements at different incident angles and transmission measurements can be carried out and combined with ellipsometric data.
-
MOX Series -
EM Research, Inc.
*Low phase noise OXCO *Interface between VSAT Modems and Frequency Converters *Robust housing is gasket sealed for weather resistance *OCXO iwth low G-sensitivity available *Single or dual multiplexer *Single or dual bias tee *Available in various OCXO frequencies: 10, 50, 100, 120 MHz
-
Weshine Electric Manufacturing Co., Ltd
The instrument can measure single capacitor of single phase or three-phase shunt capacitor bank without removing wires.2. The instrument has the functions of inductance, resistance and current measurement.3. The instrument has two power supply modes: External AC220 V and built-in lithium battery meet various application scenarios.
-
SY8330 -
Hong Kong Songyang Industrial Ltd.
SY8330 Series Three Phase Energy Auto-calibration System is a new generation, high precision, multifunctional energy meter calibration equipment. It uses the international’s most advanced technology and components available in 90 decade. It can be widely used to calibrate different kind of single phase energy meter both channel & three phase energy meter or multifunction power meter.
-
B&K Precision Corporation
designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more.
-
FSMR3000 -
Rohde & Schwarz GmbH & Co. KG
The R&S®FSMR3000 is a microwave measurement receiver to calibrate signal generators and attenuators with one single instrument. Most important features provided are tuned RF level measurements, level measurements, analog modulation and spectrum analysis. Additionally, the R&S®FSMR3000 can be equipped with powerful hardware for high-end phase noise test supplementary to the standard phase noise test with the spectrum analyzer.
-
RediSep Alumina -
Teledyne LABS
Single use alumina columns run under normal phase conditions and offer different selectivity to silica. Neutral alumina columns are useful when samples are acid sensitive and prone to degradation on normal phase silica gel.Choose basic alumina to purify basic compounds without basic modifiers such as TEA or ammonium hydroxide. This avoids solvent swapping, washing the chromatography system, or contaminating subsequent runs.
-
109 -
North Atlantic Industries
NAI’s 109 is an AC- or DC-Powered Power Monitor used to monitor voltage, frequency, and phase characteristics of single- or three- phase power lines. This allows normal operation of system loads when the power-line characteristics are within predetermined limits.The 109 monitor provides three separate control circuits and output relays indicating the condition of each line characteristic. It is ideally suited for rugged defense and industrial applications.
-
Carl E. Holmes Company
Variable DC power supplies are AC to DC power supplies with a variable DC output. The output can be varied with an SCR controller. The AC input power can be single-phase or three phases. With single-phase AC input, the DC output ripple is very high (50%). With three-phase AC input, the DC output ripple is low (5%). This would be a key benefit for selecting three-phase AC input instead of a single phase.
-
Kikusui Electronics Corp.
complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*.
-
T&R Test Equipment Ltd.
Our primary current injection test sets cover from 750A through to 6000A. Available in single phase, testing applications include testing and timing of under and over current relays, circuit breakers and CT ratio testing.
-
DRB Series -
TDK-Lambda Corp.
*Single and Three Phase Input Models*High Efficiency, up to 94%*Peak Power Capability Models, 20% for 2sec*Long E-Capacitor Life*Class 2 Models to UL 1310*Class 1 Div 2 for Hazardous Locations
-
M-310 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*The unique U type CT enabled to measure the load current of single or three phase cable without separating the cable to the wires.*Leakage current measurements with least affection from the external magnetic field.*Wide current measurements.(AC0.01mA-300A)
-
Spectronix
The Acousto-Optic Deflector (AOD) RF Driver is a three channel, three phase high power driver amplifier intended to drive devices such as the Harris H-902. The driver accepts a single low level RF input and produces three high power phase shifted outputs. The driver features adjustable gain, power monitoring, and programmable automatic protection features. The exceptional linearity and headroom allow the use of multi-tone and complex waveforms with minimal distortion.